6-5

MLC 104 Plus Series • Labeling, installation, and Mounting

PRELIMINAR

Y

• Ground each faceplate directly to an earth ground, as shown below.

MLC 104 IP Plus Rear Panel

RUN

100

Ground each faceplate
to the earth
ground.

or

• Tie each faceplate to its circuit board ground via a ground pin on one of the

connectors. Refer to the product’s user’s manual to determine the correct circuit

ground pin.

A

D

B C

E

A

D

B C

E

ON

1

2

A

D

B C

E

A

D

B C

E

Ground each
faceplate to
the circuit
ground.

N

Do not tie a product’s faceplate to both a separate earth ground and the circuit

ground (via a connector pin). If you tie a product to two different ground
sources, you may introduce ground loops or other grounding‑related problems
into the system.

N

Do not tie a faceplate to a product’s circuit ground if the product will be installed

in a grounded metal electrical box.

N

Only metal faceplates can and should be grounded. Plastic faceplates do not

require a grounding wire.