1

Introduction

This chapter provides a functional overview of a Redundant Power System (RPS).

RPS

 

Overview

An RPS (redundant power system) consisting of a C2RPS‐CHAS2 chassis and 
C2RPS‐PSM power supplies is a simple and economical solution to provide backup 
power for one or two SecureStack C2 Ethernet switch devices (one for each switch device). 
When a C2RPS‐PSM is connected to a switch device, it continuously monitors the internal 
power supply of the switch device. If a power interruption is detected, the C2RPS‐PSM is 
automatically triggered to provide power for the switch device, preventing an 
interruption in network traffic. The end result is a more reliable network infrastructure, 
protecting the network from a single source of failure from a network device power 
supply.

Depending on your system requirements, the C2RPS‐CHAS2 chassis can consist of the 
following components to provide redundant power for one or two switch devices:

•

One C2RPS‐CHAS2 chassis

•

One or two C2RPS‐PSMs (one per SecureStack switch device)

•

One or two AC power cords (one per C2RPS‐PSM)

•

One or two C2RPS‐PSM Cables (one per C2RPS‐PSM)

For information about...

Refer to page...

RPS Overview

1-1

C2RPS-CHAS2 Chassis

1-2

C2RPS-PSM Power Supply Module

1-3

RPS Deployment Strategies

1-4

Getting Help

1-5

Note: The chassis is shipped without a PSM. The PSMs are ordered separately. Each
PSM is shipped with an interconnecting C2RPS-PSM Cable and an AC power cord

.

Advertising