- 2 -

your eyes or skin come into contact with sulphuric
acid, rinse the affected part of the body with plenty
of clear running water and seek immediate medical
assistance!

• Avoid an electric short-circuit when connecting the

appliance to the battery. Connect the positive pole
terminal clamp only to the positive pole of the batte-
ry. Connect the negative pole terminal clamp only to
the negative pole of the battery.

• Connect the terminal clamps ("–" and "+") only to

the insulated area!



Attention! Avoid damage caused by improper
use!

• Only use the appliance with the included original

parts!

• Protect the contact surfaces of the battery.

Connection

• First connect the red quick-connect terminal clamp to

the positive pole (+) of the battery.

• Then connect the black quick-connect terminal clamp

to the negative pole (-) of the battery.



The appliance can be fastened to the vehicle chas-
sis during the measurement using the magnetic strip
on the back of the appliance.

Testing a battery and generator

Battery test / start capacity

• If only the 11.5 volt LED lights up, the charge of the

battery is weak. The battery must be recharged.

• If the 12 volt LED also lights up, the battery is half

charged. Recharging of the battery is recommended.

• If the 12.6 volt LED also lights up, the battery is fully

charged and capable of starting.



Attention! Property damage!
Before charging, learn about how to maintain the
battery by reading its operating instructions!

Generator test