DIN

IBM1

IBM2

Horizontal start position
(from the left edge)

14.8 mm

14.8 mm

14.8 mm

105 characters

ISO7811

Bit density

210 bpi ± 5%

75 bpi ± 5%

Recording direction

Left to Right

Left to Right

Preamble

61 bits

21 bits

SOM (Start sentinel)

D

B

Recordable characters

0-9, A, B, C, D, E

0-9, A, E

EOM (End sentinel)

F

F

LRC Parity

even

even

Postamble

64 bits

24 bits

Maximum number of
recordable characters (1
block)

105 characters

35 characters

Maximum number of
recordable characters (2
block)

—

—

Number of separator

—

—

Center of vertical position

14.0 mm

14.0 mm

Horizontal start position
(from the left edge)

14.8 mm

14.8 mm

Character conversion table

PR2 emulation and ESC/P2+ESC/MC mode

Function

Recording codes

Crt

ASCII

Line
code

DIN/ISO,
ISO8484

IBM3604

VRC

BIT4

BIT3

BIT2

BIT1

0

0

30H

crt

crt

1

0

0

0

0

1

1

31H

crt

crt

0

0

0

0

1

PLQ-30/PLQ-30M User’s Guide

Product Information 123