16-CLEANING AND MAINTENANCE

Technical Dept. - All rights reserved - Reproduction is prohibited

REPLACEMENT OF OVERPRESSURE SILICON DAMPER FOR COMBUSTION CHAMBER

The overpressures sillicon damper “G” for combustion chamber (fig. A) shall be replaced with a new one yearly (during the periodical

maintainance) in order to keep the overpressure safety system efficient.

For replacement use the following instructions

•

remove the top

•

remove the first lateral ceramic covering / metal covering (in accordance with the model)

•

unscrew the screw-washer-damper-spacer shown in fig. A/C (operate same way on both sides)

Install the new kit as follows:

•

Prepare the screw-washer-damper-spacer alligned as shown in fig.C and screw them in the structure.

•

screw it completely

Check now the proper compression of dampers, using the gauge included in the kit:

•

lay the gauge on the lid (fig.B); the gauge has to lay completely, while the head of the screw has to be in contact with the gauge. If

it’s not the case, register the screw accordingly.