14-SAFETY DEVICES AND ALARMS

ALARM ALERTS

If there is an operational anomaly, the stove enters the alarm phase displaying the problem that has taken place through a code, a brief

description of the alarm type and an acoustic warning.

The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the panel and

helpful tips to solve the problem.

B = RESET (cancels alarm)

C = INFO (provides information on the alarm type)

E = MENU

WRITTEN ON THE

DISPLAY

TYPE OF PROBLEM

SOLUTION

A01

NO IGNITION

The fire does not ignite.

(without acoustic alarm)

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has no visible

deposits or unburnt pellets.

Check whether the ignition plug becomes hot.

Empty and clean the brazier before relighting.

A02

NO FLAME

The fire goes out abnormally.

(without acoustic alarm)

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has no visible

deposits of unburned pellets.

A03

PLT SAFETY

Pellet tank temperature is too high

Wait for the cooling phase to end, cancel the alarm and reduce

pellet loading (SETTINGS MENU - Pellet recipe). If the alarm

persists, contact the service centre.

A04

FUMES TEMP

Fumes temperature is too high

Wait for the cooling phase to end, cancel the alarm and reduce

pellet loading (SETTINGS MENU - Pellet recipe). If the alarm

persists, contact the service centre.

A05

OBSTRUCTION

Chimney flue clogged

Verify brazier clogging, smoke duct, lower compartment and

door closing. If the alarm persists, contact the service centre.

B

E

RESET

C

OBSTRUCTION

A05