Chapter 2
INSTALLATION AND USE MANUAL
page
6
Theoretical concepts for installation
Technical service - MCZ S.p.A. all rights reserved - Reproduction prohibited
2. INSTALLATION CONCEPTS ACCORDING TO UNI 10683
2.1. OPERATING AREA
For good operation and good heat distribution, the appliance should be
positioned in a place where the air required for combustion can flow (at
least 60 m
3
/h must be available) according to installation standards and
current regulations in the country of installation.
The room volume must not be less than 60 m
3
.
Air must enter through permanent openings on the walls (near the
product) that open outdoors with a minimum section of 150 cm
2
.
These openings (air vents) must be made so as not to be obstructed in
any way.
Air can also be taken from adjacent rooms as long as these are
equipped with outdoor air vents and are not bedrooms or bathrooms or
rooms where fire hazards exist such as garages, wood sheds or
flammable material warehouses, strictly observing that stated in current
regulations.
•
The product may not be installed in bedrooms,
bathrooms and where another heating appliance
is installed without autonomous air flow
(chimney, stove, etc.).
•
Placing the appliance in explosive environments
is prohibited.
•
The floor of the room where the product is to be
installed must be strong enough to support its
weight.
•
In the event of wood floors, install a protective
covering in accordance with current regulations
in the country of installation.
•
If walls are not flammable, install the product at
least 5 cm. from the walls.
2.2. PRECAUTIONS
The product must be installed in a suitable location that permits routine
opening and maintenance operations.
The room must be:
•
set for room operating conditions
•
equipped with an adequate smoke exhaust system
•
equipped with outdoor ventilation