12433-5-0606

Locating Gas Supply

The gas line can enter the unit either through the floor or outside wall.

The gas line opening should be made at this time. Location of the opening

will be determined by the position of floor joists and the valve and union

used for servicing.

Note: Never use plastic pipe. Check to confirm whether your local codes

allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is always

best to consult your local authority and installation code.
The use of the following gas connectors is recommended:

— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and

Fittings

— ANS Z21.45 Assembled Flexible Appliance Connectors of Other

Than All-Metal Construction

The above connectors may be used if acceptable by the authority having

jurisdiction. The state of Massachusetts requires that a flexible appliance

connector cannot exceed three feet in length.