Slide 12, Troubleshooting during installation – Marshall Electronics CV360-CGB User Manual

Page 12

Advertising
background image

- 12 -

1. Video output through HD-SDI or HDMI on monitor is blue or black.
If the SDI OUT & HDMI connection is bad or wrong.
If the resolution setting is not suit for device.
Or it is not suitable CABLE or transmission distance is too long.
♦ Check SDI OUT & BNC JACK connection & HDMI connection.
♦ Check the resolution of camera and match with device.

2. HD-SDI output does not display properly.
There will be defect or error message on display if cable doesn't batch the signal requirement, If
user doesn’t use 75Ω BNC cable for HD- SDI connection
♦ Please check Camera output‘s BNC CABLE and both connected jacks on recording unit input and
camera output, also check other connected device’s BNC is 75 Ω
♦ Change the cable and the HD-SDI connections
♦ Please use 75 Ω BNC adapters for extension cable.
♦ HD-SDI CABLE’s limited range.
5C-HFBT(Maximum up to 100m)

3. There is cross line, breaking and disconnection On HD-SDI display.
If HD-SDI out BNC’s connection is bad, Cause is that the short circuit of cable, not proper
cable or excess the limited range.
♦ Please check for proper cable for HD- SDI and Cable distance is optimal.
♦ Please check the connection of BNC between HD-SDI and BNC (bad connection,
connected condition)

4. If the HD-SDI display’s output is not on the correct location right of left.
If the resolution mode is not set properly, when user connects it to the receiver
directly or monitor’s resolution setting is not correct.
♦ Please check the resolution output value of camera.
♦ Please check the monitor and DVR resolution setting value.
♦ Some of monitor can’t support 1080 60P, 1080i resolution.

4. Troubleshooting during Installation

Advertising