Marwin Valve 3L/T 2100F-A Series 3-Way Ball Valve User Manual
Scope, Applicability, Caution
 
3170 Wasson Road • Cincinnati, OH 45209 USA
Phone 513-533-5600 • Fax 513-871-0105
[email protected] • www.marwinvalve.com
I & M 3L/T-2100F Series
Installation & Maintenance Instructions for
Marwin 3L/T-2100F Series Three Way Ball Valves
Warning: Marwin Valve ball valves must only be used, installed and repaired in accordance with these Installation & 
Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event of leak-
age or other malfunction, call a qualified service person; continued operation may cause system failure or a general 
hazard. 
Please read these instructions carefully!
Your Marwin Valve product will provide you with long, 
trouble-free service if it is correctly installed and main-
tained. Spending a few minutes now reading these in-
structions can save hours of trouble and downtime later. 
When making repairs, use only genuine Marwin Valve 
parts, available for immediate shipment from the factory.
Scope
This manual is intended as a guide to assist customers 
in the storage, installation, and maintenance of Marwin 
3L/T-2100F Series three way ball valves. Subsequent 
additions or special instructions will be provided 
for special ball valves, critical service or customer 
requirements.
Applicability
This manual is applicable to the 3L/T-2100F-A (threaded 
end) and 3L/T-2100F-F/G (flanged end) Series Marwin 
three way ball valves.
Caution
1. Valve pressure ratings are based on many variables,
including valve series and size, as well as body, seat 
and bolt material. Verify that application does not 
exceed the pressure or temperature rating on the 
nameplate. 
2. Always depressurize the line with the valve in the
OPEN position before disassembly. Cycle valve in 
depressurized line before loosening bolts.
3. Wear protective equipment and take appropriate
precautions to safeguard against injury caused by 
the discharge of trapped fluids.
4. Use only Marwin recommended spare parts for
maintenance.
5. To ensure safety and maintain warranty, never
modify valve in any way without prior approval from 
Marwin. 
Storage
Lubricant is used on all internal surfaces. This may be 
removed with a solvent if found objectionable. All valves 
are adequately packed in a strong cardboard case in 
such a way as to avoid any possible damage during 
transport and storage.
 
If ball valves are not destined for immediate use, the fol-
lowing precautions should be taken:
1. If possible, leave the ball valves in their packing 
cases during the period of storage.
2. Ball valves must remain in open position during this time.
3. In order to prevent damage, protective plastic covers 
on valve ends should not be removed until immedi-
ately prior to installation.
4. It is advisable to store the valves in dry conditions.
Ball valves should be protected to safeguard against 
humidity, moisture, dust, dirt sand, mud, salt spray 
and seawater.
5. Valves with actuators shall be stored in dry
conditions.
6. Valves to be stored for a long period of time should
be checked by the quality control personnel every 
six months; every three months when valves are 
automated. 
 
1/2”-2” Typical
6” Typical
2-1/2”-4” Typical
- 3L/T 2100F -F Series 3-Way Аква техника 3T3300 Series 3-Way Brass Аква техника 3L3400 Series 3-Way Brass Аква техника DM9000 Series 4600F Series Brass Аква техника, 3 Piece Swing Out 600 Series - 633FTRS Series - Brass Аква техника 600 Series - 666FTTS - Brass Аква техника 600 Series - DM600-xxx-BR Series - Brass Аква техника 600 Series - 666RTTS - Brass Аква техника