MEDC DB20C User Manual

Page 4

Advertising
background image

11/13

© MEDC 2013

3.0 INSTALLATION

DB20

The unit is mounted via 2 off Ø7mm fixing holes in the U-shaped stirrup/mounting bracket. If required,

the unit can be initially placed via the Ø13mm central hole in the stirrup. The unit can then be rotated to

the required position and fixed via the other holes.

The fixing holes have been designed to accept an M6 screw or bolt.

DB20C

For DB20C installation details please see the section 8.

Access to Terminals

Unscrew the 3 off M5 screws (4.0mm A/F hexagon key) holding the cover assembly to the base. The

screws are retained in the cover. Remove cover to gain access to the interior of the terminal chamber.

Once termination is complete, carefully replace the cover back onto the enclosure, avoiding damage to

the mating surfaces. Evenly tighten the 3 off M5 screws (4.0mm A/F hexagon key) in the cover,

ensuring the O-ring is correctly seated in its groove during re-assembly. Ensure

4.0 OPERATION

The operating voltage of the unit is stated on the unit label.

Different sound levels can be obtained by selecting the transformer tappings in the unit, via the

terminals in the Exe chamber. See table below for available tappings:

WIRING DETAILS

POWER

TRANSFORMER

TAPPINGS

8W VERSION

4W VERSION

1:2

8W

4W

2:3

4W

2W

3:4

2W

1W

1:3

1.5W

0.75W

2:4

0.75W

0.375W

1:4

0.4W

0.2W



Advertising