Retrotec Blower Door with DM32 User Manual

Blower door quickguide

Advertising
background image

Water in the tube will result in erroneous readings.

Blower Door QuickGuide

Step 1:

Prepare the building

□

Close outside doors and windows.

□

Open all interior doors leading to conditioned spaces.

□

Turn gas, hot water, to Pilot.

□

Fireplaces and stoves must be cold with doors

closed (cover ashes).

□

Shut off HVAC, combustion appliances, exhaust fans,

dryers, A/C and furnaces.

See: “Residential Pressure & Air Leakage Testing Manual” for

additional information.

□

Set up the Door Panel.

See Your Door Panel QuickGuide

□

Connect the yellow tube between yellow ports

marked “Ref B” on fan and gauge. If the fan has a

green port (“Input B”), connect the green tube.

□

Connect one end of the Speed Control Cable to the

fan and another to the gauge.

□

Connect the red tube to the red port on the gauge.

□

Pass the red tube through the Door Panel and toss

the end at least 5 feet away from the fan’s airstream.

Remove or cover

ashes.

Turn gas valve

to Pilot.

Close all windows

and outside doors.

□

Place gauge near fan, or attach gauge to Door Panel.

□

Install the fan blowing outdoors. Cover the fan.

□

Connect the fan power plug to a wall outlet.

Step 2:

Install the system