GFCI RECEPTACLE

After starting the engine, check the GFCI for proper functioning by the following test procedure.

・ Push the TEST button, The RESET button will pop out exposing the word TRIP. Power is now

off at the outlets protected by the GFCI, indicating that the device is functioning properly.

・ If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician.

・ To restore power, push RESET button.

CONNECTING TO DOMESTIC CIRCUIT (HOUSE WIRING)

(a) When connecting a Subaru generator to a house wiring, generator output power must be taken

from the 240V-4P receptacle.

(b) Install a transfer switch.

A transfer switch must be installed to transfer the load from the commercial power source

to the generator. This switch is necessary to prevent accidents caused by the recovery from

power outage. Use a transfer switch of the correct capacity.

Install transfer switch between the meter and the fuse or AC breaker box.

If the RESET button pops out during operation, stop the generator
immediately and call a qua lified electrician for checking generator and
a ppliances.

This generator is neutral bonded type.
If a generator is to be connected to residential or commercial power
lines, such as a stand by power source during power outage, a ll
connections must be by a licensed electrician.
Failure in connection may result in dea th, personal inj ury ,damage to
generator, damage to a ppliances, damage to the building's wiring or fire.

IF the neutral wire of house wiring is grounded, be sure to ground the
ground terminal of the generator, Otherwise an electric shock may occur
to the operator.