Thermo Pride Premiere XT 16 SEER User Manual

Page 15

Advertising
background image

15

FIGURE 16: Thermostat Chart - Two Stage AC – Variable Speed Furnaces

AC 31A

Two Stage Air Conditioner – Variable Speed Air Handler

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*PP32U70124

THERMOSTAT

AUX

Auxiliary Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Thermostat Installer Setup

0170-System Type-must

be set to 8-2 Heat/2 Cool

Multistage Conventional

C

24 – Volt Common

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22U00124

THERMOSTAT

W2

Second Stage Heat

R

24 – Volt Hot

(Heat XFMR)

R

24 – Volt Hot
(Cool XFMR)

E/W1

Emergency Heat

E/W1

First Stage Heat

Connection of the “C”

terminal, 24-volt common

is optional when used with

batteries

Thermostat Installer Setup

1-System Type-must

be set to 6-2 Heat/2 Cool

Multistage Conventional

COM

24 – Volt Common

R

24 – Volt Hot

W1

First Stage Heat

W2

Second Stage Heat

Y1

Single Stage Compressor

Y/Y2

Second or Full

Stage Compressor

O

Reversing Valve

Energized in Cool

X/L

Malfunction Light

HUM

Humidity Switch

Open on Humidity Rise

VARIABLE SPEED

AIR HANDLER CONTROL

G

Fan

VARIABLE SPEED

AIR HANDLER

1

AV

ID MODELS

SV

MV

EAC (24VAC out)

Electronic Air Cleaner

HUM OUT

(24VAC out)

Humidifier

Part Number:

S1-2HU16700124

2

Part Numbers:

SAP = Legacy

159481 = 031-09157

1

External Humidistat

(Optional)

Open on Humidity Rise

2

24VAC Humidifier

(Optional)

24VAC

Electronic Air Cleaner

(Optional)

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

Move the HUM STAT

jumper to “YES”

if humidistat is to be used.

Refer to AH documentation

for W1 and W2 electric

heat staging options.

Thermostat Installer Setup
15-Compressor Protection

-must be set to 5

Advertising