3 independent operation - remote sensing, Independent operation - remote sensing -7 – KEPCO RA 19-4C Operator Manual User Manual
Page 25

RA 19-4C 121013
2-7
2.4.1.2.3 INDEPENDENT OPERATION - REMOTE SENSING
Remote sensing is accomplished by connecting +Load to (S+) and –Load to (S–). Figure 2-5
illustrates remote sensing for PS1 and PS2 using wires connected to the I/O mating connector
for PS1 and wires connected to the mating Euro plug for PS2.
NOTE: The internal DIP switch settings established at the factory for positions 1 and 2 of the
associated DIP switch MUST be changed to OFF (open) if this option is chosen.
Positions 3 and 4 (connecting sense lines in parallel) and Position 5 (current share) must be set
to OFF. Configure Positions 6, 7, and 8 (alarms) per PAR. 2.5.
FIGURE 2-5. INDEPENDENT OPERATION, REMOTE SENSING FOR PS1 AND PS2 USING
EXTERNAL WIRING AT I/O MATING CONNECTOR OR EUROBLOCK, SIMPLIFIED DIAGRAM