Table 2. power supply ratings and specification – KEPCO RCW 750W Series User Manual

Page 6

Advertising
background image

2

RCW 750W 120607

TABLE 2. POWER SUPPLY RATINGS AND SPECIFICATION

SPECIFICATION

DESCRIPTION

Input Voltage

Nominal: 100-120Vac or 200-
240Vac

Range: 85-264 Vac

Range 125-370 Vdc

Polarity insensitive. Safety ratings apply for a-c
input operation only.

Input Source Frequency

Nominal 50/60 Hz, Range 47-440 Hz. (At 440 Hz the leakage current exceeds the
VDE safety leakage specification limit).

Brownout Voltage

80 V ac min

Input Current: (Maximum Load At 50°C with
Nominal Output Voltage)

120V ac

12.0A RMS max., and 8.0A RMS max for the
3.3V output model

240V ac

6.0A RMS max., and 4.0A RMS max for the
3.3V output model

Input Protection

Units Are Protected Against Shorts By An Input Fuse. Fuse Value 20.0A At 250
Volts

Input Surge at 25° C from cold start; resistor

and thyristor soft start circuit reduces start-up
surge. (see Figure1)

120V ac

20.0A max. first surge

240V ac

40.0A max. first surge

Stabilization

Typical

Maximum

Source Effect (min - max) (85 to
132 V ac, 170 to 264V ac)

0.05%

(1)

0.1%

(1)

Load Effect, measured at sens-
ing terminals (0%-100% load
change)

0.1%

(2)

0.3%

(2)

Temperature Effect (–10° to
71°C)

0.5%

1.0%

Combined Effect (envelope,
Source, Load and Temperature)

± 0.7%

± 1.5%

Drift (8 hours at 25°C)

0.2%

0.5%

Output Holding Time:

Output is maintained for 30 milliseconds typical upon input interruption (20 milli-
seconds minimum) with nominal 120 volts AC input voltage and output load at
50°C current rating.

Start-up Time

900 msec maximum, 500 typical.

Overvoltage Protection

When the Power Supply goes into an overvoltage condition, the output is cut OFF.
To restart (reset) the unit, it is necessary to remove the AC input power, wait 40
seconds, and then to reconnect the AC input power.

Operating Temperature:

-10 to 70°C (see Figure 2)

Storage Temperature:

-25°C to +75°C

Humidity:

10% to 95% relative humidity, noncondensing, Wet Bulb temperature <35°C

Isolation
(at 25°C ambient, 65% relative humidity)

Between input and case, 2000 Vac for 1 minute
Between input and output terminal, 2000 Vac for 1 minute, and 3000 Vac with Y
capacitors removed. Cutout current is 20mA

Insulation Resistance: (at 25°C, 65% relative
humidity)

Between output and case, input and case, and input and output, 100 Megohms
minimum (500 Vdc)

Leakage Current:

0.50 mA max at 120 Vac (U.L. Method 50 to 60 Hz)
0.75 mA max at 240Vdc (VDE Method 50 to 60 Hz, two terminal connection)

Vibration:
(non-operating 1 hour on each of three axes,
Power Supply is fixed on its bottom side)

5-10 Hz., 10mm amplitude, 10-200 Hz., 64.3ft./s

2

( 19.6M/s

2

)

1) 2 mV typ, 4mV maximum for the 3.3 volt Model
2) 10mV typ, 25mV maximum for the 3.3 volt Model

Advertising