Mounting Instructions
4. Install the air chamber by aligning the
air chamber assembly and plunger 
with the pintle hook. Make sure the 
plunger moves freely within the pintle 
hook plunger chamber (Figure 7). 
Attach the air chamber to the assembly 
(Figure 12). Bolt together the air 
chamber assembly and pintle hook using 
two (2) new 3/4” diameter Grade 8 
bolts, ASTM Grade C lock nuts, and 
hardened 3/4” washers (Figure 8).
5. Torque all six (6) new 3/4" diameter
Grade 8 bolts and ASTM Grade C lock 
OVUTUPGUMCT	/tN
QFS 
SAE J429.
6. Connect the air supply to the air chamber
and check for proper operation.
IMPORTANT: Consult the vehicle
manufacturer for 
information regarding 
proper plumbing, 
air source, and 
overpressure protection.
7. Adjust the plunger as needed per detailed
instructions in Section 8, page 12.