Electrical connection, Warning – DE DIETRICH DOV1145 User Manual

Page 8

Advertising
background image

8

EN

2 / INSTALLING YOUR APPLIANCE

ELECTRICAL CONNECTION

Single phase 20A Meter
220-240V~ 50Hz

Electrical socket

2 pin +e

ea

arrtth

h

to IEC 60083 standard

220-240 V~ single-phase line

Power

supply cable

length 1.60 m approx.

10A fuse or residual current

circuit breaker

The appliance must be correctly installed to
ensure electrical safety. During fitting and
maintenance operations, the appliance must
be unplugged from the electrical system;
fuses must be switched off or removed.

The electrical connections are made before
the appliance is installed in its housing.
Ensure that:
- the electrical installation has sufficient
voltage,
- the electrical wires are in good condition,
- the diameter of the wires complies with the
installation requirements.
Your oven must be connected via a
(standardised) power cable with 3 conductors of
1.5mm2 (1 live + 1 neutral + earth) which must be
connected to a 220-240V~ single-phase system.

by means of a 1 live + 1 neutral + earth IEC
60083 standard power socket or via an all-
pole cut-off device in compliance with the
installation rules.

It should be possible to disconnect from the
mains or using a sheet making current, or by
incorporating a switch in accordance with
fixed piping installation requirements.

Warning

The safety wire (green-yellow) is connected

to the appliance’s

terminal and must be

connected to the installation’s earth.
In the case of connection to an electric wall
socket, it must remain accessible after
installation.

The circuit should be protected with a
10 Amp fuse.
If the power cable is damaged, it must be
replaced by the manufacturer, its After-
Sales Service Department or a similarly
qualified person to avoid danger.

Advertising