S P E C I F I C AT I O N S

Measuring Ranges:

300A/3000A

Output Sensitivity:

1mV/0.1mV/A (AC coupled)

Accuracy: (at 25°C)

±1% of range

Frequency Range:

10Hz to 5kHz

Phase Error:

±1º (45 to 65 Hz), ±10º (at 5 kHz)

L i n e a r i t y :

±0.2% of reading from 10% to 100% of range

Position Sensitivity:

±2% of range, cable >25mm (1”) from coupling

External Field:

±1% with cable >200mm (8”) from head

Minimum Load:

100kW for specified accuracy

Noise Level:

1.0mV rms (0.3% of range)

Operating Te m p e r a t u r e :

-20°C to 85°C (-4°F to 185°F) Electronics

Storage Te m p e r a t u r e :

-20°C to 85°C (-4°F to 185°F) Electronics

Gain Va r i a t i o n :

±0.08%/°C

Common Mode Vo l t a g e :

Voltage between the Output the Earth must not
exceed 30V

Power Supply:

2 x AA/MN1500 LR6 (1.5V) batteries

Battery Life:

4000 hours, 3000 hours typical (4 months cont.)

Low Battery Indication:

Red LED flashing

External Power:

Battery eliminator, via 2.1mm connector, 3V DC
Socket type A16M500

S a f e t y :

BS EN61010-1: 1993, 600V CATIII Pol. Deg 2

E M C :

EN61326: 1998

E n c l o s u r e :

IP5X, Flame retardant UL94-VO rated

M a t e r i a l :

Valox 357 X

Output Connections:

Hypotronics connector type DO1EEB306FST

We i g h t :

0.19 kg (0.4 lb)

Measuring Head
Cable length:

610mm (24 inches), double insulated

Cable Diameter:

14.3mm (0.562 inches)

Bend Radius:

38.1mm (1.5 inches) minimum

Connecting Cable:

2m (78.7 inches) long, double insulated

Material:

TPE rubber, Polypropylene, UL94-VO rated

Operating Temperature: -20°C to +90°C (-4°F to 194°F) Head
Storage Temperature:

-40°C to +105°C (-40°F to 221°F) Head

Safety:

BS EN 61010-1: 1993, 600V CAT III Pol. Deg 2

Weight:

0.18kg (0.4 lb)

Advertising