Standard Accessories:
Test leads (pair), banana plug style, bead Type-K Thermocouple, batteries, user’s manual,
& soft carrying case.

Replacement Part Numbers:
Test Leads (pair): MTL-90B, Bead Type-K Thermocouple: TPK-59, Carrying Case: SV-U

Electrical Specifications
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 73°F ± 9°F
(23°C ± 5°C) & less than 75% R.H.
True RMS Model ACD-14 TRMS FX ACV, AcµA & ACA clamp-on accuracies are specified
from 5% to 100% of range or otherwise specified. Maximum Crest Factor are < 1.96 at
full scale & < 3.92 at half scale, and with frequency spectrums, besides fundamentals, fall
within the meter specified AC bandwidth for non-sinusoidal waveforms.

DC Voltage

RANGE

Accuracy

400.0 mV

0.3% + 4d

4.000V, 40.00V, 400.0V

0.5% + 3d

600V

1.0% + 4d

NMRR: >50dB @ 50/60Hz

CMRR: >120dB @ DC, 50/60Hz, Rs=1kΩ

Input Impedance: 10MΩ, 30pF nominal

(1000MΩ for 400.0mV range)
Max Hold (where applicable)
Specified accuracy ± 50 digits for changes
> 25ms in duration

AC Voltage

RANGE

Accuracy 1)

50Hz -- 500Hz

4.000V, 40.00V,
400.0V

1.5% + 5d

600V

2.0% + 5d

CMRR: >60dB @ DC to 60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal

ACA Current (Clamp-on)

RANGE

Accuracy

50Hz / 60Hz

40.00A

1.9% + 8d

400.0A

1.9% + 8d*

600A**

unspecified

*Accuracy specified to 350A continuous,
and 400A for 60-second max with 5
minutes cool down interval
**Added range to indicate instantaneous
over-range current values
TRMS model ACD-14 TRMS FX accuracy is
specified from 10% to 100% of range.

RANGE

Accuracy*

-20°C TO 300°C

2% + 3°C

-4°F TO 572°F

2% + 6°F

Type-K Temperature

*Type-K thermocouple range & accuracy
not included

Advertising