GENERAL SPECIFICAtION

display : 3-3/4 digits 4000 counts LCD display

Update Rate : 3 per second nominal

Polarity : Automatic

Operating temperature : 0 °C to 40 °C; < 80% RH for temperature up to 31 °C

decreasing linearly to 50% RH at 40 °C

Altitude : Operating below 2000m; Indoor use

Storage temperature : -20

o

C to 60

o

C, < 80% RH (with battery removed)

temperature Coefficient : nominal 0.15 x (specified accuracy)/

o

C @(0

o

C ~ 18

o

C or

28

o

C ~ 40

o

C)

Low Battery : Below approx. 2.4V

Power Supply : 3V coin battery IEC-CR2032

Power Consumption : 2.8 mA typical except that 3.3 mA typical for ACA function

APO timing : Idle for 30 minutes

APO Consumption : 5 μA typical

dimension : 190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in)

Weight : 139 gm approx

Jaw opening & Conductor diameter : max 26 mm

Accessories : Test leads, battery installed, user’s manual, & soft carrying pouch;

Special Features : 30ms Max Hold; Data Hold; Relative Zero mode

Safety: Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2

nd

Ed., EN61010-1

2nd Ed., UL61010-1 2nd Ed. CAT III-600 Volts ac & dc; Pollution degree : 2

EMC: Conforms to EN61326-1.

This product complies with requirements of the following European Community
Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low
Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or
intense electromagnetic fields in the vicinity of the equipment may disturb the
measurement circuit. Measuring instruments will also respond to unwanted
signals that may be present within the measurement circuit. Users should exercise
care and take appropriate precautions to avoid misleading results when making
measurements in the presence of electronic interference.