9

Power: 1.5 volt battery x2, R03/SIZE AAA.
Power: Single standard 1.5-volt “AAA” battery x2 (NEDA 24A).
Battery life: Typically 50 hours with carbon-zinc; 100 hour with alkaline.
Dimensions: 240 Ч 70 Ч 41 mm (9.5 x 2.8 x 16 IN).
Weight: Approx. 7.7 oz. (220g).

DC Volts (Auto Ranging)

Ranges

Accuracy

400.0mV, 4.000V, 40.00V, 400.0V, 600V

± (0.5% rdg + 2 dgts)

400mV range (ACD-22SW only)
Input impedance: 400mV:>100Me ; 4V:10Me; 40V to 600 V: 9.1 Me
Overload protection:
600 VDC or AC rms

AC Volts (TRUE RMS) (Auto Ranging)

Ranges

Resolution

Accuracy

4V, 40V, 400V

50 to 500 Hz

± (1.2% rdg + 8 dgts)

600V

50 to 500 Hz

± (1.5% rdg + 8 dgts)

Crest Factor:

3

AC coupled true rms specified from 5% to 100% range
Input impedance: 4 V:10 Me ; 40 V to 600 V: 9.1 Me
Overload protection:
600 VDC or AC rms

AC Current (TRUE RMS) (Auto Ranging)

Ranges

Frequency

Accuracy

40.00A, 400.00A

50 to 60 Hz

± (2.0% rdg + 10 dgts)

Crest Factor:

3

AC coupled true rms specified from 5% to 100% range
Overload protection: 400A AC

Resistance (Auto Ranging)

Ranges

Accuracy

400.0e , 4.000ke , 40.00ke , 400.0ke

± (1.0% rdg + 5 dgts)