Amprobe ACDC-100 Clamp-On-Multimeters User Manual

Page 12

Advertising
background image

11

Electrical (23 °C ± 5 °C) < 75% Rh

DC Voltage

RANgE

Accuracy

400.0 mV

± (0.3% + 3dgts)

4.000V, 40.00V, 400.0V

± (0.5% + 3dgts)

600V

± (1.0% + 4dgts)

Resolution : 0.1 mV on 400 mV range
nMRR : >50dB @ 50/60hz
CMRR : >20dB @ DC, 50/60hz, Rs=1kΩ
input impedance : 10MΩ, 30pf nominal (1000MΩ for 400.0mV range)
Max input : 600VDC/VAC rms

AC Voltage

RANgE

frequency

Accuracy

400.0mV

1)

50hz to 500hz

± (4.0% + 4dgts)

4.000V, 40.00V, 400.0V

50hz to 60hz

± (1.0% + 4dgts)

4.000V, 40.00V, 400.0V

60hz to 500hz

± (1.5% + 4dgts)

600V

50hz to 500hz

± (2.0% + 4dgts)

Resolution: 0.1 mV on 400 mV range

CMRR : >60db @ DC to 60hz, Rs= 1kΩ
input impedance: 10MΩ, 30pf nominal
Crest factor (ACDC-100 TRMS): < 1.6: at full scale; < 3.2: at half scale
Max input: 600VDC/VAC rms

1)

Selection by Range button manually, and is specified from AC 40mV (AC 60mV for ACDC-
100 TRMS) and up

Resistance

RANgE

Accuracy

400.0Ω

± (0.8% + 6dgts)

4.000kΩ, 40.00kΩ, 400.0kΩ

± (0.6% + 4dgts)

4.000MΩ

± (1.0% + 4dgts)

40.00MΩ

± (2.0% + 4dgts)

Resolution: 0.1 Ω on 400 Ω range
open Circuit Voltage : 0.4VDC typical

Continuity Tester
open Circuit Voltage:

0.4Vdc typical

Range:

400.0Ω

Accuracy:

± (1.5% + 6dgts)

Audible threshold:

between 10Ω and 120Ω.

Diode Tester
open Circuit Voltage

< 1.6 Vdc

Test Current (Typical)

0.4mA