9

Input Impedance: 1 MΩ
Overload Protection: 600 V rms

AC Voltage (AC40C)

Range

Accuracy (40 – 450 Hz)

Resolution

400 V

±(1.5 %rdg +10 dgt)
50-60Hz;(+/-3% rdg + 15dgts) 400Hz

0.1 V

600 V

±(1.5 %rdg +10 dgt)
50-60Hz;(+/-3% rdg + 15dgts) 400Hz

1 V

Input Impedance: 1 MΩ
Measuring method: Dual slope integration. Average Sensing,
rms indication. Overload Protection: 600 V rms

AC Current (AC40C/AD40B)

Range

Frequency

Accuracy

Resolution

40A

50/60 Hz

±(2.5%rdg +10dgt)

0.01A

40A

60 – 400 Hz

±(4.0%rdg +10dgt)

0.01A

400A

50/60 Hz

±(2.5%rdg +10dgt)

0.1A

400A

60 – 400 Hz

±(4.0%rdg +10dgt)

0.1A

Overload Protection: 660 A
Accuracies are specified for conductor centered in the jaw. If
the conductor is not centered, an additional error of max 1.5%
can result.
Measuring method: Dual slope integration. Average Sensing,
rms indication.

Resistance (AC40C)

Range

Accuracy

Resolution

400 Ω

±(1.0 %rdg + 5 dgt)

0.1 Ω

Max open circuit voltage, AC40C: -1.2 V nominal
Overload Protection, AC40C: 600 Vrms