Amprobe 30XR-A Professional-Digital-Multimeter User Manual

Page 7

Advertising
background image

1

30XR-A Digital Multimeter

Contents

Making Measurements ...............................................................................2

Verify Instrument Operation...................................................................2
Correcting an Overload (

o) Indication W ............................................2

Measuring DC Voltage .................................See Figure

-1-

...................2

Measuring AC Voltage .................................See Figure

-2-

...................2

Preparing for Current Measurements ....................................................2
Measuring DC Current .................................See Figure

-3-

...................3

Measuring AC Current .................................See Figure

-4-

...................3

Measuring Resistance .................................See Figure

-5-

...................3

Measuring Continuity (<50 Ohms)...............See Figure

-6-

...................3

Checking Diodes ..........................................See Figure

-7-

...................3

Measuring NCV (Non-Contact Voltage)........See Figure

-8-

...................4

Testing Battery Voltage (1.5 and 9 volt).......See Figure

-9-

...................4

Additional Features ....................................................................................4
Product Maintenance..................................................................................5

Battery and Fuse Replacement.....................See Figure

-10-

.................5

Repair .........................................................................................................5

WARRANTY ...........................................................................................6

Electrical Specifications.............................................................................7

XWSafety Information

To Avoid possible electric shock, personal injury, damage to the meter or the
equipment under test, adhere to the following practices:

Do not exceed the maximum overload limits per function (see specifications)

nor the limits marked on the instrument itself. Never apply more than 600 VDC
between the test lead and earth ground.

Inspect DMM, test leads and accessories before every use. Do not use any

damaged part.

Never ground yourself when taking measurements. Do not touch exposed

circuit elements or probe tips.

Do not operate the instrument in an explosive atmosphere.

Exercise extreme caution when measuring voltage >20 V // current >10 mA //

AC power line with inductive loads // AC power line during electrical storms //
current, when the fuse blows in a circuit with open circuit voltage >600 V //
servicing CRT equipment.

Always measure current in series with the load – NEVER ACROSS a voltage

source. Check fuse first. Never replace a fuse with one of a different rating.

Do not change the position of the Function/Range Switch while the MIN MAX or

the HOLD feature is enabled. Erroneous readings will result.

Remove test leads before opening battery or case to change battery or fuses.

Use

rs Ma

nua

l

Advertising