Amprobe 34XR-A Professional-Digital-Multimeter User Manual

Page 17

Advertising
background image

11

RESISTANCE

Ranges: 400

, 4k

, 40k

, 400k

, 4M

,

40M

Resolution: 100 m

Accuracy: ±(1.0 % rdg + 4 dgts) on
400

to 4M

ranges

±(2.0 % rdg + 5 dgts) on 40M

range

Open circuit volts: -0.45 V dc typical,
(-1.2 V dc on 400

range)

Overload protection: 1000 V dc or
750 V ac rms

CAPACITANCE

Ranges: 4µF, 40µF, 400µF, 4000µF
Resolution: 1 nF
Accuracy:
±(5.0 % rdg + 10 dgts) on 4µF range
±(5.0 % rdg + 5 dgts) on 40µF to
400µF ranges
±(5.0 % rdg + 15 dgts) on 4000µF range
Test voltange: < 3.0 V
Test Frequency: 25Hz
Input protection: 0.315A/1000V fast blow
ceramic fuse 6.3×32mm on µA/mA input

TEMPERATURE

Ranges: -20 °C to 1000 °C, -4 °F to 1832 °F
Resolution: 1 °C, 1 °F
Accuracy:
±(2.0 % rdg + 4 °C) -20 °C to 10 °C
±(1.0 % rdg + 3 °C) 10 °C to 200 °C
±(3.0 % rdg + 2 °C) 200 °C to 1000 °C
±(2.0 % rdg + 8 °F) -4 °F to 50 °F
±(1.0 % rdg + 6 °F) 50 °F to 400 °F
±(3.0 % rdg + 4 °F) 400 °F to 1832 °F
Overload protection: 1000 V dc or
750 V ac rms

FREQUENCY

Ranges: 4k, 40k, 400k, 4M, 40MHz
Resolution: 1 Hz
Accuracy: ±(0.1 % rdg + 3 dgts)
Sensitivity:
10 Hz to 4 MHz: >1.5 V ac rms;
4 MHz to 40 MHz: >2 V ac rms, <5 V ac rms
Minimum pulse width: > 25 ns
Duty cycle limits: > 30 % and < 70 %
Overload protection: 1000 V dc or
750 V ac rms

DUTY CYCLE

Ranges: 0 to 90 %
Resolution: 0.1 %
Pulse widh: >10 µs
Frequency range: 40 Hz to 20 kHz
Accuracy: (5V logic ) ±(2.0% rdg + 5 dgts)
Overload protection: 1000 V dc or
750 V ac rms

CONTINUITY

Audible indication: < 35

Response time: 100 ms
Overload protection:1000 V dc or
750 V ac rms

DIODE TEST

Test current: approximately 1.2 mA
Accuracy: ±(1.5 % rdg + 3 dgts)
Resolution: 1 mV

Open circuit volts:

3.0 V dc typical

Overload protection: 1000 V dc or
750 V ac rms

ADDITIONAL FEATURES
µA
mA

, 10A Test Lead Connection: Beeps

to warn test leads are connected to
measure current while Function/Range
Switch is not set to a measure current.
MIN MAX: Displays the minimum or
maximum value detected while making a
measurement.
HOLD: Holds the latest reading on the
display.

RANGE:

Manual range mode.

Backlight:

Backlight auto-off

approximately 60 seconds
Auto Power off: 30 minutes, typical
REPLACEMENT PARTS
TL36 Test Lead Set with Alligator clips
FP300 mA fuse - Fuse Pack .315A/1000V

(4 each)

FP100 10A fuse - Fuse Pack 10A/1000V

(2 each)

XR-TA Input Adapter for K-type

thermocouple

TP255 K type thermocouple
XR-H2 Magne-Grip

®

Holster, clip, magnet,

and strap