Amprobe AM-42 Multimeters User Manual

Page 6

Advertising
background image

6

E.M.C.: Meets EN61326 (1997, 1998/A1), EN61000- 4-4 (1995), & EN61000-4-3 (1996)
In an RF Field of 3V/m:
Capacitance function is not specified
Other function ranges:
Total accuracy = Specified accuracy + 45d
Performance above 3V/m is not specified

Overload Protection:
AM-42 & AM-47: 600VDC & VAC rms
AM-45: 450VDC & VAC rms
Low Battery: Below approx. 2.4V
Power Supply: 3V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC)

Power Consumption (typical):
AM-42 & AM-45: 2mA
AM-47: 6mA for Voltage functions on Auto-V

Ω position, and 2mA for other functions

APO Consumption (typical): 2.2

µA

APO Timing:
AM-42: Idle for 30 minutes
AM-45 & AM-47: Idle for 3 minutes
Dimension / Weight: L122mm x W65mm x H13mm / Approx. 100 gm

Special Features:
AM-42: Data Hold, and 30ms MAX Hold
AM-45 & AM-47: AutoCheck

TM

(Automatic V &

Ω Selection), and EF-Detection

Accessories: Battery installed, and User’s manual

Electrical Specification
Accuracy is given as +/- (% of reading digits + number of digits) or otherwise specified @ 23

o

C +/- 5

o

C and less

than 75% R.H.

------------------------------------------------------------------------- --------------------------------------------------------------------------

DC Voltage (AM-45 & AM-47)

RANGE Accuracy
6.000V 0.5%+3d
60.00V 1.0%+5d
450.0V

1)

1.2%+5d

600.0V

2)

2.0%+5d

600.0V

3)

1.5%+5d

AM-45 Input Impedance:

AutoCheck

TM

Lo-Z DCV: 160k

Ω, 160pF nominal

AM-47 Input Impedance:

AutoCheck

TM

Lo-Z DCV: 833k

Ω (4.2kΩ when

displaying “Auto”), 90pF nominal

Hi-Z DCV: 5M

Ω, 90pF nominal

NMRR: > 30dB @ 50Hz/60Hz
CMRR: > 100dB @ DC, 50Hz/60Hz; Rs=1k

DCV AutoCheck

TM

Threshold:

> +1.2VDC or < -0.6VDC nominal

1)

AM-45 AutoCheck

TM

DCV only

2)

AM-47 AutoCheck

TM

DCV only

3)

AM-47 Hi-Z DCV only

AC Voltage (AM-45 & AM-47)

RANGE Accuracy
50Hz -- 60Hz

6.000V, 60.00V, 450.0V

1)

,

600.0V

2)

1.5%+5d

CMRR: > 60dB @ DC to 60Hz, Rs=1k

AM-45 Input Impedance:

AutoCheck

TM

Lo-Z ACV: 160k

Ω, 160pF nominal

AM-47 Input Impedance:

AutoCheckTM Lo-Z ACV: 833k

Ω (4.2kΩ when

displaying “Auto”), 90pF nominal

Hi-Z ACV: 5M

Ω, 90pF nominal

ACV AutoCheck

TM

Threshold:

> 1.5VAC (50/60Hz) nominal

1)

Range for AM-45 only

2)

Range for AM-47 only

Advertising