Resistance measurement, Battery test – Amprobe DM7C Digital-Multimeter User Manual

Page 8

Advertising
background image

Resistance Measurement

Prior to any resistance measurement it has to be ensured that the resistor to be

tested does not have voltage across it. Failure to comply with this prescription can

lead to dangerous user injuries or cause instrument damage.

Addition-

ally, foreign voltages falsify the measurement result.

1) Select measurement range (2000!, 20k!, 200 k! or 2 M!) via measurement

function selection switch.

2) Connect the black test lead to the COM socket and the red test lead to the

socket.

3) Connect the test leads to UUT.

4) Read the measurement result displayed on the screen.

If display shows ”1” on the left, change selection to next highest resis.-range.

Battery Test

1) Select measurement range 9V or 1.5V via measurement function selection switch

.

2) Connect the black test lead to the COM socket and the red test lead to the

BATTERY TEST socket.

3) Connect test leads to UUT/Battery.

4) Read the measurement result displayed on the screen.

6

Advertising