6

Resistor / Capacitor / Continuity / Diode

• For better measurement accuracy of small value

capacitance, subtract the residual capacitance of
the Meter and leads from measurement.

• Under diode mode, LCD displays “bad” when

measuring a diode conducted at forward and
reverse bias.

• LCD displays capacitance mode when no

measurement at Auto-sense mode.

• Under Auto-sense mode, do not measure a

broken component, a unknown component, or a
component with mixed electrical characteristic,
such as measuring a resistor and a capacitor in
parallel. The meter may display incorrectly.