Amprobe PM-60 Pocket-Meter User Manual

Page 15

Advertising
background image

9

Storage temperature: -20 to +60°C (-4°F to 140°F), 0 to
80% RH (batteries not fitted).
Temperature coefficient: Add 0.2 x (Specified accuracy) /
°C, < 18°C (64.4°F), > 28°C (82.4°F).
Shock vibration: Sinusoidal vibration per MIL-T-28800E (5
~ 55 Hz, 3g/0.007lb maximum).
Drop Protection: 4 feet drop to hardwood on concrete
floor.
Overvoltage category: IEC 61010-1 300V CAT. Ⅲ., 600V
CAT. II.

CAT

Application field

The circuits are not connected to mains.

The circuits are directly connected to Low-
voltage installation.

The building installation.

The source of the Low-voltage installation.

Operating altitude: 2000m (6562 ft)
Pollution degree: 2
EMC: EN 61326-1
Dimensions (WxHxD): 56 x 12 x 112 mm (2.2 x 0.5 x 4.4 in)
Weight: 115g (0.25 lb)
Accessories: Battery (installed), carry case and Instruction
Card.

Electrical Specifications

Accuracy is ± (% reading + number of digits) at
23°C/73.4°F ± 5°C/41°F < 80% RH.

Advertising