Intensité AC (50...400 Hz)

Calibre

Résolution

Précision

40 mA

0.01 mA

400 mA

0,1 mA

± (1,5% d.L. +3 D)

10,00 A

0,01 A

± (2% d.L. +3 D)

8 A continue,

10 A pendant 10 minutes maximum suivis d’une 20 minutes période de

refroidissement

Protection surcharge:

Fusibile (mA) :

FF500mA / 700V / 50kA , 6x32mm

Fusibile (A) :

F 10A/600V/50 kA, 6x32mm

Résistance

Calibre

Résolution

Précision

Protec. Surcharge

400 !

0.1 !

4 k!

1 !

40 k!

10 !

400 k!

100 !

± (1,5% d.L. +3 D)

600 Veff

4 M!

1 k!

40 M!

10 k!

Tension test

<3,2 V DC

Test Continuité

Calibre

Résolution

Test Tension

Protec. Surcharge

400 !

0.1 !

< 3,2 V DC

600 Veff

Signal: < 60 ! (±50%)

Test de diode

Calibre

Résolution

Test Tension

Protec. Surcharge

1.0 V

1 mV

< 3,2 V DC

600 Veff

12