Specifications
General Specifications
Display and Update Rate: 3-5/6 digits 6000 counts; Updates 5 per second
nominal
Operating Temperature: 0
°C - 40 °C
Operating Relative Humidity: Maximum 80% R.H. up to 31
°C, decreasing linearly to
50% R.H. at 40
°C
Altitude: Operation below 2000 m
Storage Temperature: -20
°C ~ 60 °C, < 80% R.H. (with battery removed)
Temperature Coefficient: Nominal 0.15 x (specified accuracy)/
°C @
(0
°C ~ 18 °C or 28 °C ~ 40 °C), or otherwise specified
Sensing: Average sensing
Overload Protection: 450 V dc and V ac rms
Low Battery: Below approx. 2.4 V
Power Supply: 3 V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC)
Power Consumption (typical): 2 mA
APO Consumption (typical): 2.2 µA
APO Timing: Idle for 3 minutes
Dimension / Weight
L 113 mm x W 53 mm x H 10.2 mm / Approx. 78 gm
Special Features
AutoTect
(Automatic V and Ω selection) and VolTect (Electric Field Detection)