10

Non-Warranty Repairs and Replacement – Europe

European non-warranty units can be replaced by your Amprobe

Test Tools distributor for a nominal

charge. Please check the “Where to Buy” section on

www.amprobe.com

for a list of distributors near

you.

European Correspondence Address*

Amprobe

Test Tools Europe

P.O. Box 1186

5602 BD Eindhoven

The

Netherlands

*(Correspondence only – no repair or replacement available from this address. European customers
please contact your distributor).

Specifications

General Specifications

Display and Update Rate: 3-5/6 digits 6000 counts; Updates 5 per second
nominal
Operating Temperature: 0

°C - 40 °C

Operating Relative Humidity: Maximum 80% R.H. up to 31

°C, decreasing linearly to

50% R.H. at 40

°C

Altitude: Operation below 2000 m
Storage Temperature: -20

°C ~ 60 °C, < 80% R.H. (with battery removed)

Temperature Coefficient: Nominal 0.15 x (specified accuracy)/

°C @

(0

°C ~ 18 °C or 28 °C ~ 40 °C), or otherwise specified

Sensing: Average sensing
Overload Protection: 450 V dc and V ac rms
Low Battery: Below approx. 2.4 V
Power Supply: 3 V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC)
Power Consumption (typical): 2 mA
APO Consumption (typical): 2.2 µA
APO Timing: Idle for 3 minutes
Dimension / Weight
L 113 mm x W 53 mm x H 10.2 mm / Approx. 78 gm
Special Features
AutoTect

 (Automatic V and Ω selection) and VolTect (Electric Field Detection)



Advertising