12

DC Voltage

Range Accuracy

6.000 V

±(0.5%+3 dgt)

60.00 V

±(1.0%+5 dgt)

450.0 V

±(1.2%+5 dgt)

Input Impedance:
AutoTect

 Lo-Z V dc: 160 kΩ, 160 pF nominal

MRR: > 30dB @ 50 Hz/60 Hz
CMRR: > 100dB @ DC, 50 Hz/60 Hz; Rs=1 k

V dc AutoTect

 Threshold:

> +1.2 V dc or < -0.6 V dc nominal

AC Voltage

Range Accuracy

50 Hz – 60 Hz

6.000 V, 60.00 V, 450.0 V

±(1.5%+5 dgt)

CMRR: > 60 dB @ dc to 60 Hz, Rs=1 k

Input Impedance: AutoTect

Lo-Z V ac: 160 k

Ω, 160 pF nominal

Hi-Z V ac: 5 M

Ω, 90 pF nominal

ACV AutoTect

Threshold: > 1.5 V ac (50 Hz/60 Hz) nominal