Amprobe MAN02 Manometers User Manual

Page 12

Advertising
background image

8

MAINtENANCE
The meter is calibrated in house before shipping. when properly maintained, the meter will
maintain its accuracy as specified.

Cleaning
Use a damp cloth and mild soap to clean the case of the MAN15 Manometer, do not use harsh
detergents or abrasives as these may mar the finish or damage the unit’s case with an adverse
chemical reaction.

SPECIFICAtIoNS

operating Conditions

Compensated temperature range: 0~50 °C (32~122 °f)

operating temperature range: 0~50 °C (32~122 °f)

Storage temperature range: -20~60 °C (-4~140 °f)

operating humidity Max. 80% Rh


Power Supply : 9 volt battery
exceeding Maximum pressure will cause permanent sensor damage.
Range: 0 ~ ±2 psi (MAN02)
0 ~ ±15 psi (MAN15)
0 ~ ±30 psi (MAN30)

Power Supply :
Conversion & Resolution

1 psi =

Resolution

inch of h

₂o

0.401

0.01

psi

0.0145

0.001

mbar

1

0.1

bar

0.001

0.001

mm of h

₂o

10.2

1

1 psi =

Resolution

bar

0.068948

0.001

mmhg

51.715073

0.5

ozin2

16.000844

0.2

Kgcm2

0.070309

0.001

psi

1

0.01

inh2o

27.679904

0.3

kpa

6.894757

0.1

fth2o

2.306659

0.02

inhg

2.036021

0.01

cmh2o

70.306955

1

mbar

68.94757

1

Accuracy: ±0.3% of full scale at ±25°C (77°f)
Repeatability: ±0.2%~0.5% of full scale
linearity / hysteresis: ±0.29% to 1% of full scale
Combined accuracy: ±1.0% of full scale
dimension: 72 x 182 x 30mm
Unit weight: Approx. 220 (o.485lb) (with battery)
Response Time: 0.5 seconds
format: baud rate: 2400 bit/sec

data bit: 8, Stop bit: 1

parity: none