SPECIFICATION

Battery Life : Approx. 100 hr
Accuracy : Typically within ± 10W/m2 [±3 BTU / (ft2*h)]
or ±5%, whichever is greater in sunlight; Additional
temperature induced error ±0.38W/m2 / °C [±0.12 BTU /
(ft2*h)/ °C] from 25°C
Operating temp. & RH : 5°C ~ 40°C, below 80%RH
Storage temp. & RH : -10°C ~ 60°C, below 70%RH
Display : 3-1/2 digits LCD with maximum reading 1999
Sampling Time : Approx. 0.25 second
Resolution : 0.1W/m2 ; 0.1 BTU /(ft2*h)
Accuracy : < ±3/year
Over-input : Display shows ”OL”
Range : 1999W/m 2 ; 634 BTU /(ft 2 * h).
Dimensions : 132(L) x 60(W) x 38 (H)mm
Weight : Approx. 150g.
EMC : This instrument is EMC-compliant and has
undergone compatibility tests according to EN61326-1:
2006

- EMC: Conforms to EN61326-1.

This product complies with requirements of the
following European Community Directives: 89/ 336/
EEC (Electromagnetic Compatibility) and 73/ 23/ EEC
(Low Voltage) as amended by 93/ 68/ EEC (CE Marking).
However, electrical noise or intense electromagnetic
fields in the vicinity of the equipment may disturb the
measurement circuit. Measuring instruments will also
respond to unwanted signals that may be present within
the measurement circuit. Users should exercise care
and take appropriate precautions to avoid misleading
results when making measurements in the presence of
electronic interference.