Specifications
General Specifications

Display: 3 ¾ digit large scale liquid crystal display (LCD)
Display Count: 4000 counts
Measuring Rate: 1.5 times per second
Overrange Display:

0o is displayed for

Ω functions. Actual value is shown

for A, V, and temperature functions.

Automatic Power Off Time: Approximately 10 minutes after power on
Low battery indication: The

N symbol is displayed when the battery

voltage drops below the operating level for accurate results.

Power: Single standard 9 V battery, NEDA160A.
Battery Life: 200 hours with an alkaline 9 V battery.

Environmental Specifications

Indoor Use
Calibration: One year calibration cycle
Operating Temperature:

0 °C to 30 °C at

≥80 % R.H.

30 °C to 40 °C at

≥75 % R.H.

40 °C to 50 °C at

≥45 % R.H.

Storage Temperature: -20 °C to 60 °C at 0 to 80 % R.H. (battery removed)

P, )

Overvoltage Category:

IEC 61010-1 CAT III - 600 V, CAT II 1000 V, Pollution Degree 2
EN61010-2-032
CAN/CSA C22.2 No. 1010.1-92
CAN/CSA C22.2 No. 1010.1B-92
CAN/CSA C22.2 No. 1010.2.032-96

Altitude:

≤2000 M (6562 Feet)

Conductor Size:

32 mm diameter (1.25 in)

EMC: EN61326-1.
Shock Vibration: Sinusoidal vibration per MIL-PRF-28800F (5 to 55 Hz, 3 g

maximum)

Drop Protection: 4 foot drop to hardwood on concrete floor

Electrical Specifications

Accuracy:

±(% reading + number of digits) at 23 °C ±5 °C at <80 % R.H.

Temperature Coefficient:

Add 0.2 x (Specified Accuracy)/

°C, <.18 °C,

>28 °C.