5

Agency Approvals:

EMC

This product complies with requirements of the following European

Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/

EEC (Low Voltage) as amended by 93/68/EEC (CE Marking).

However, electrical noise or intense electromagnetic fields in the vicinity of

the equipment may disturb the measurement circuit. Measuring instruments

will also respond to unwanted signals that may be present within the

measurement circuit. Users should exercise care and take appropriate

precautions to avoid misleading results when making measurements in the

presence of electronic interference

Electrical Specifications

Accuracies at 23°C ± 5°C, <75% RH.

Resistance

Ranges: 20, 200Ω, 2, 20, 200kΩ, 2, 20MΩ
Resolution, 20Ω range: 10mΩ
Accuracy: 20Ω range: ±1.2% rdg (zero adjust)

200Ω range: ±0.5% rdg +3dgt

2k to 2MΩ rgs: ±(0.5% rdg +1dgt)

20MΩ rg: ±(2.0% rdg +2dgt)

OL Protection, all ranges: 350VDC or AC RMS
Open Circuit Voltage; 20Ω range: 6.5VDC; 200Ω range: 3.0VDC; other ranges:

1.2VDC

Continuity

Audible Indication, 2kΩ rg: at R ≤30Ω
Response time: 800ms approx
OL Protection: 350VDC or AC RMS

Diode Test

Test Current: 1mA (approx.)
Test Voltage: 3.0VDC typical
Accuracy: ±(1.5%rdg +1dgt)
Display: Forward Junction Voltage
OL Protection: 350VDC or AC RMS

Micro Wave Diode Test

Test Current: 1.3mA (approx.)

Test Voltage: 8.0VDC typical

Accuracy: ±(3.0%rdg +1dgt)

Display: Forward Junction Voltage
OL Protection: 350VDC or AC RMS

Capacitance

Ranges: 200pF, 2, 20, 200nF, 2, 20, 200, 2000µF
Accuracy*:200pF to 200nF: ±(1.0% rdg +3dgt)

2µF to 200µF rgs: ±(2.0% rdg +3dgt)

2000µF range: ≤1000µF ±(3.0% rdg +3dgt)

>1000µF ±(5.0% rdg +5dgt)

Note: In lower ranges, substract 6 points residual offset reading from result
Test Frequency: 200p to 2µF: 1000Hz; 20, 200µF ranges: 100Hz; 2000µF range:

10Hz