Amprobe VPC-20 Voltage-Continuity-Tester User Manual

Amprobe Measuring instruments

Advertising
background image

Digital Voltage and Continuity Tester

Model VPC-20

Instruction Manual

m

Safety Information

• Never use the tester if it or test leads appear damaged.

• Never apply more than 600V DC or 600V AC rms. between any terminal and

earth ground

• When using the probes, keep your fingers behind the finger guard on

the probes.

• Turn off power to the circuit under test before cutting, desoldering, or

breaking the circuit. Small amounts of current can be dangerous.

• Use caution when working with voltage above 60V dc or 30V ac rms. Such

voltages pose a shock hazard.

Automatic Operation

The tester automatically turns on when you short the two test probes or place the

probes across a complete circuit.When turned on, the tester powers up in continuity

mode. If a dc or ac voltage greater than about 4.0V is present across the inputs, the

tester switches to dc or ac voltage mode.The tester automatically shuts down after

approx. 4 minutes of inactivity.

Continuity testing

Turn off circuit power before testing. Beeper indicates shorts lasting 1 ms or longer.

SHORT 10KΩ

OPEN

Specifications:

Display: Large 1999 count LCD display with function and high voltage warning indication.

Maximum Voltage Between any Terminal and Earth Ground: 600V dc; 600V ac rms,

Over-voltage Category III 600V

Safety: Complies with EN61010-1:1993 for use in over-voltage CAT III environments

Pollution Degree: 2

For indoor use only

EMC Regulations: EN50081-1, EN50082-1

Polarity: Automatic, (-)negative polarity indication.

Over-range: “1” mark indication

Low battery indication: The “BAT” is displayed when the battery voltage drops below

the operating level

Measurement rate: 2 times per second, nominal

Continuity test: Audible threshold 0-10KW, Continuity beeper 2KHz

Input Impedance: 400KΩ

Temperature: 5 °C(41°F) to 40°C (104°F)

Altitude: Operating: 2000m; Storage: 10,000m

Relative Humidity: 80% for Temp up to 31C decreasing linearly to 50 % RH at 40C

Pollution Degree: 2

For indoor use only

Battery Type: AA (2) NEDA 15F or IEC R6

12V DC

240V AC

Measuring Voltage

Refer to Automatic Selection

DC Voltage (Volts dc>4.0V)

600V dc maximum

AC Voltage (Volts dc>4.0V)

600V ac maximum

50Hz to 400Hz

Function

Range

Accur acy(%rdg.+digits)

V AC(50Hz ~400Hz)

600V

+(2.9%+8)

V DC

600V

+(1.5%+2)

Continuity test: Audible threshold 0~10K

Ω,Continuity beeper 2KHz.

Overload protection: AC/DC 600V

Diminsions/wt.:215x96.3x37.5mm/312g