MTP 15HD A Series • Installation

VersaTools

®

MTP 15HD A Series • Installation

VersaTools

®

MTP 15HD A Series, cont’d

4.

Circuit overloading

— Consideration should be given to

the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be
used when addressing this concern.

5.

Reliable earthing (grounding)

— Reliable earthing of

rack-mounted equipment should be maintained.
Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as
the use of power strips).

Rack mounting instructions

For optional rack mounting, mount the MTP on any of the
following rack shelves:

RSF 123 VersaTools

®

19" 1U rack shelf kit (part #60-190-20)

(figure 1)

RSB 123 VersaTools 19" basic 1U rack shelf (part #60-604-21)

RSU 126 6" deep 1U rack shelf kit (part #60-190-10)

RSB 126 6" deep basic 1U rack shelf (part #60-604-11)

RSU 129 standard 9.5" universal 1U rack shelf kit
(part #60-190-01) (figure 2)

RSB 129 basic 9.5" universal 1U rack shelf (part #60-604-02)

(2) 4-40 x 3/16" Screws

Use 2 mounting holes on

opposite corners.

VersaTools Basic
Rack Shelf

Quarter Rack Width False

Faceplate

MT

P T

VG

A R

S

MT

P T

VG

A R

S

MT

P T

VG

A R

S

Figure 1 — Mounting the MTP on a VersaTools shelf

End Unit Receiver DIP Switch

Set the receiver’s rear panel End Unit DIP switch up only if
either

of the following is true:

The receiver being configured is the only receiver
connected to the transmitter.

The receiver being configured is the last receiver in a
daisy-chained system.

If one or more receivers are connected to the Buffered Output
RJ-45 connector of the receiver being configured, set that
receiver’s End Unit switch down.

Installation

CAUTION

Installation and service must be performed by
authorized personnel only.

The 1U high, quarter rack width, MTP transmitter and all
receiver models can be mounted on a rack shelf, to a rack
without a shelf, under a desk or tabletop, or on a projector
bracket.

Rack mounting

UL guidelines

The following Underwriters Laboratories (UL) guidelines
pertain to the installation of the MTP transmitter or receiver into
a rack.

1.

Elevated operating ambient temperature

— If the

equipment is installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack
environment may be greater than room ambient.
Therefore, consider installing the equipment in an
environment compatible with the maximum 122° F (50° C)
ambient temperature (Tma) specified by Extron.

2.

Reduced air flow

— Installation of the equipment in a

rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.

3.

Mechanical loading

— Mounting of the equipment in the

rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.

VersaTools

®

MTP 15HD A Series • Installation

7

6

VersaTools

®

MTP 15HD A Series • Installation