Supported raid levels – Avago Technologies MegaRAID SAS 9280-16i4e User Manual

Page 10

Advertising
background image

Page 10

LSI Corporation Confidential

|

June 2010

MegaRAID SAS 9280-16i4e RAID Controller Quick Installation Guide

Supported RAID Levels

Reinstall the computer cover, and reconnect the power cords. Turn on the power to
the computer. Make sure that the power is turned on to the SAS devices and the
SATA II devices before or at the same time that the power to the host computer is
turned on. If the power is turned on to the computer before it is turned on to the
devices, the computer might not recognize the devices.

The firmware takes several seconds to initialize. During this time, the controller
scans the ports.

8. Run the WebBIOS Configuration Utility

Run the WebBIOS Configuration Utility to configure the groups and the virtual
drives. When the message

Press <Ctrl><H> for WebBIOS appears on the

screen, immediately press CTRL+H to run the utility.

NOTE: Refer to the MegaRAID SAS Software User’s Guide for detailed steps on
configuring groups and virtual drives.

9. Install the Operating System Driver

The controller can operate under various operating systems, but you must install
the software drivers first.

The MegaRAID Universal Software Suite CD includes the software drivers for the
supported operating systems, along with documentation. You can view the
supported operating systems and download the latest drivers for RAID controllers
from the LSI web site at:

http://www.lsi.com/cm/DownloadSearch.do

. Access the download center, and

follow the steps to download the driver.

Refer to the MegaRAID SAS Device Driver Installation User’s Guide on the MegaRAID
Universal Software Suite
CD for more information about installing the driver. Be sure
to use the latest service packs that are provided by the operating system
manufacturer and to review the readme file that accompanies the driver.

Supported RAID Levels

This RAID controller supports drive groups using the following RAID levels:

„

RAID 0 (data striping): Data is striped across all drives in the group, enabling very
fast data throughput. There is no data redundancy. All data is lost if any drive fails.

„

RAID 1 (drive mirroring): Data is written simultaneously to both drives in the drive
group, providing complete data redundancy if one drive fails. RAID 1 supports an
even number of drives from 2 to 32 in a single span.

„

RAID 5 (drive striping with distributed parity): Data is striped across all drives in
the group. Part of the capacity of each drive stores parity information that
reconstructs data if a drive fails. RAID 5 provides good data throughput for
applications with high read request rates.

„

RAID 6 (drive striping with distributed parity across two drives): Data is striped
across all drives in the group and two parity drives are used to provide protection
against the failure of up to two drives. In each row of data blocks, two sets of parity
data are stored.

Advertising