MegaRAID SAS 9280-16i4e RAID Controller Quick Installation Guide
Controller Installation
J2B2
x4 SAS Ports 4-7 internal connector
SFF-8087 x4 internal mini SAS connector
Connects the controller by cable to SAS
drives or SATA 2 drives.
J2D1
Standard edge card connector
The RAID controller interfaces with the
host system though a standard edge card.
This interface provides power to the board
and an I
2
C interface connected to the I
2
C
bus for IPMI.
J3B1
x4 SAS Ports 8-11 internal connector SFF-8087 x4 internal mini SAS connector
Connects the controller by cable to SAS
drives or SATA 2 drives.
J4A1
Module CPLD
1x8-pin connector
Reserved for LSI use.
J4A2
Activity LED header
2-pin connector
Connects to an LED that indicates activity
on the drives connected to the controller.
J4A3
Global drive fault LED header
2-pin connector
Connects to an LED that indicates whether
a drive is in a fault condition.
Table 1:
Jumpers and Connectors (Continued)
Jumper/
Connector
Type
Description
J4A2
+ve
a
k
-ve
J4A3
a
k
+ve