Avago Technologies AcceleRAID 352 User Manual

Page 17

Advertising
background image

Hardware Installation

Manual No. DB11-00027-00

5

Installing the AcceleRAID 352 into the System Board

1. With the power off, plug the AcceleRAID 352 controller into an

available 32-bit or 64-bit PCI slot on the system board (refer to
Figure 5). The 32-bit slot is short, the 64-bit slot is longer.

Figure 5. Plugging the AcceleRAID 352 into a PCI Slot

2. Set the SCSI ID on each internal drive to a unique address between

0 and 15, but do not use address 7, as it is reserved for the controller.
See the documentation that comes with your drives for instructions
on how to do this.

Caution

If internal and external drives are used, be sure that no
drive addresses are duplicated. External SCSI cabinets
usually automatically assign drive addresses
according to the drives’ location in the cabinet.

3. Disable termination on all SCSI drives connected to the controller. See

the documentation that comes with your drives for instructions on how
to do this. (Termination must be enabled on the last device, if
applicable.)

4. Enable termination power on all SCSI drives connected to the

controller. See the documentation that comes with your drives for
instructions on how to do this.