Compressor module horsepower selection chart – Emerson SCROLL SZO44 User Manual

Page 36

Advertising
background image

30

2006SSD-75 R4 (10/10)

Dual-Compressor Module

Technical Support and Service

Compressor Module
Horsepower Selection Chart

Module Model Number: SZO56C1A-EDE-240

Configuration

Suction

Press

(PSIG)

Max Flow/HP as a function of discharge pressure at maximum flow

rate (Note 1)

MCFD)

70

80

90

100 110 120 130 140 150

One Module Package

-7.5

MCFD

43

42

HP

19

20

0

MCFD

97

96

96

95

94

94

94

93

93

HP

19

21

23

25

26

27

29

30

32

5

MCFD

131 130 130 129 128 128 127 127 126

HP

21

23

24

26

27

29

30

31

33

10

MCFD

165 164 164 163 163 162 161 160

HP

23

24

26

27

28

30

31

33

15

MCFD

198 198 197 197 196 195

HP

25

27

28

30

31

32

20

MCFD

232 232 232 231 230 229

HP

27

28

30

31

31

32

25

MCFD

265 264 264 264

HP

31

31

32

33

Two Module Package

-7.5

MCFD

86

84

HP

37

40

0

MCFD

194 193 191 190 188 188 188 187 185

HP

39

43

46

49

52

55

58

60

63

5

MCFD

262 261 259 258 257 256 255 253 252

HP

42

45

49

52

54

57

60

63

66

10

MCFD

329 329 328 327 325 323 321 320

HP

45

48

51

54

57

60

63

65

15

MCFD

396 396 395 394 392 390

HP

51

54

57

59

61

63

20

MCFD

464 465 463 463 460 458

HP

54

56

59

62

63

64

25

MCFD

530 529 528 527

HP

62

63

64

65

NOTES:
1. Max flow using varibable speed drive, compressors operating at 80 Hz. max speed.
2. Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig
3. Performance data to be used as an estimation guide only and is subject to change without notice

Advertising
This manual is related to the following products: