Compressor module horsepower selection chart – Emerson SCROLL SZO44 User Manual

Page 37

Advertising
background image

31

2006SSD-75 R4 (10/10)

30

2006SSD-75 R4 (10/10)

Dual-Compressor Module

Technical Support and Service

Compressor Module
Horsepower Selection Chart

Module Model Number: SZO44C1A-EDE-244

Configuration

Suction

Press

(PSIG)

Max Flow/HP as a function of discharge pressure at maximum

flow rate (Note 1)

MCFD)

70

80

90

100 110 120 130 140 150 160 170 180 190

One Module Package

-7.5

MCFD

33

32

HP

14

15

0

MCFD

75

74

74

73

72

72

72

72

71

71

70

70

70

HP

15

16

18

19

20

21

22

23

24

25

26

27

28

5

MCFD

101 100 100

99

99

98

98

97

97

97

96

96

95

HP

16

17

19

20

21

22

23

24

25

26

27

28

29

10

MCFD

127 126 126 126 125 124 124 123 123 122 122 121 121

HP

17

18

19

20

22

23

24

25

26

27

28

29

30

15

MCFD

152 152 152 152 151 150 150 149 148 148 147 147

HP

19

20

21

23

23

24

25

27

28

29

30

31

20

MCFD

179 179 178 178 177 176 176 175 175 174 173 173

HP

20

21

22

24

24

24

26

28

29

30

31

32

25

MCFD

204 203 203 203 202 202 201 200 199 199

HP

23

24

24

25

27

28

30

31

32

33

Two Module Package

-7.5

MCFD

66

64

HP

28

31

0

MCFD

150 148 147 146 145 145 144 144 143 142 141 140 139

HP

29

32

35

37

39

41

44

46

48

50

52

54

57

5

MCFD

201 201 200 199 197 197 196 195 194 193 192 191 191

HP

32

34

37

39

41

43

46

48

50

52

54

56

58

10

MCFD

253 253 252 251 250 249 247 246 246 245 244 243 242

HP

34

37

39

41

43

45

47

49

51

53

55

58

60

15

MCFD

305 305 304 303 301 300 299 298 297 296 295 294

HP

39

41

43

45

46

48

51

53

55

57

60

62

20

MCFD

357 357 356 356 354 353 352 351 349 348 347 345

HP

41

43

45

47

47

49

52

55

57

59

61

64

25

MCFD

407 407 406 405 404 403 402 400 399 397

HP

47

48

49

49

53

57

59

61

63

65

NOTES:
1. Max flow using varibable speed drive, compressors operating at 80 Hz. max speed.
2. Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig