Problem

Possible Solution

After connecting with the

USB Type-C source device,

the power LED lights

continuously blinking or

showing ASUS logo repeatly

Insufficient power supply from source USB

Type-C devices. Please follow below steps:

Press the Blue Light Filter button , and

then connect the USB Type-C cable. This

operation will enable built-in safe mode. After

displaying ASUS logo, please release the

Blue Light Filter button. After ASUS Logo

disappearing, there is “safe mode” message

OSD showing up. Once “safe mode” message

OSD disappears, please set background color

to white image or nearly white image (*1).

Press

MENU

button, main menu OSD is

showing. The upper left corner of the OSD will

display small red-colored font “S”, indicating it

is now in safe mode. Enter brightness setup,

press the up key to tune up brightness. During

the process, please note down brightness

value “Y” up until MB16AC re-start.(*2). For

example, if brightness value shows “70” and

MB16AC restarts when adjusting to “71”,

“70” is the “Y” value to note down and is the

highest brightness value for the connecting

USB-C source device.

Press

MENU

button, main menu OSD is

showing. The upper left corner still indicate

“S” as safe mode. Adjust the OSD brightness

value to “Y”

Close the OSD and press Low Blue Low Filter

hot key for 5 seconds to turn off safe mode.

Complete.

*1: White color background will consume higher power, so it’s better to use

white color background to test the power limit from source USB Type-C

device.

*2: If MB16AC does not re-start when adjusting to value 100, that means

source USB Type-C device has sufficient power supply.