Carrying handle, Automatic suction shut-off, How to empty wet or dry contents from tank – Eureka 2800 Series User Manual

Page 11: Blower

Advertising
background image

1. Place hose coupling into blower

outlet.

2. Use 1 1/4 inch diameter hose

and wand(s) to direct air into
small areas.

3. Use optional 2 1/2 inch diameter

hose, wand, and blower nozzle
for large areas.

Blower Nozzle (optional)

Carrying Handle

CAUTION:

Do Not attempt to carry wet/dry vac by lid or detachable blower handle.
Only use carrying handles molded onto tank.

Automatic Suction Shut-Off

NOTE: The unit must be used in upright position at all times, otherwise the ball

float will automatically shut-off the suction.

The automatic suction shut-off functions when tank is full of liquid. As the tank fills, the
ball float (inside cage) rises until it seats itself against bottom of motor. This shuts off the
suction causing the motor sound to become higher in pitch. When this happens, empty
tank.

The automatic suction shut-off also functions if the cleaner tips over. To continue use,
turn cleaner off and set it upright. Wait a few seconds to allow motor to come to a
complete stop so ball drops; restart the motor.

How To Empty Wet or Dry Contents From Tank

NOTE: Turn off power switch and unplug electrical cord before emptying tank.

1. Raise hose above tank to drain

excess liquid into tank.

(For wet pick-up only.)

2. Remove hose.

3. Remove lid.

4. Empty contents into suitable

drain for liquids or container for
dry contents.

5. Replace lid and hose and

continue cleaning.

Blower

The hose, tank, and accessories must be cleaned before using as a blower.

NOTE:

Always wear safety goggles (not provided). If operated for a prolonged

period of time, ear protection is recommended. Never point blower toward
people, animals, or objects that may be injured/damaged by flying debris.
These units must NOT be used to power a paint sprayer or to supply air
to any other sprayer.

Blower
Outlet

Hose Coupling

11