A.6 indispensable signal pins of s5u1c330mxd1 – Epson S1C33 User Manual

Page 27

Advertising
background image

APPENDIX S5U1C330MXD1 BOARD

S1C33 FAMILY DEBUG MONITOR

EPSON

OPERATION MANUAL

21

A.6 Indispensable Signal Pins of S5U1C330MxD1

When using the S5U1C330M2S it is not absolutely necessary to connect the NMI, RESET and DEBUG
switches/signals on the S5U1C330MxD1 board. If these switches are not used, the target board can be connected to
the S5U1C330MxD1 using only the five signals as shown below.

Example:

Connecting the target board to S5U1C330MxD1 with five wires

User target board

The wire length must be within 10 cm.

12

10

5
4

1

GND

SCLK

SIN
SOUT

V

CC

Figure A.6.1 Connection example using indispensable pins

The NMI, RESET and/or DEBUG signals should be connected if necessary.

Advertising