On start

When this function is “On,” the projector is automatically turned
on just by switching MAIN ON/OFF SWITCH on.

Note:

Be sure to turn the projector off properly (see “Turning Off the Projector” on page 28).
If the projector is turned off in the wrong steps, the On start function does not operate
properly.

Setting

Display

This function decides whether to display On-Screen Displays.

On . . . . .shows all the On-Screen Displays.
Off . . . . .sets On-Screen Displays disappeared except;

On-Screen Menu

“Power off?” message

P-TIMER

“No signal” message

“Please wait...” message

“Searching...” message

Input search

With this function “On”, the projector automatically starts input
signal search from Input 1 to Input 5 when turning on the
projector. This automatic search stops at the Input where the
projector detects any input signal connected.

Power management

Time left until Lamp off

Press the SELECT button at
Power management and this
box appears. Choose “Off” to
disable the timer setting,
“Ready” or “Shutdown” to
enable the timer setting.

Power management

For reducing power consumption as well as maintaining the lamp
life, the Power Management function starts the count down when
the input signal is interrupted and no button is pressed for 30
seconds or more.

If the input signal is interrupted and no button is pressed for 30
seconds or more, the timer display with the message “No signal”
appears on the screen. The count-down of the set time gets
started. The count-down time can be set between 1 and 60
minutes.

When the count-down time has been elapsed, the lamp is turned
off to cool itself down. The LAMP indicator dims during this
cooling-off period. The next operation depends on the setting as
follows :

Ready . . . . . .When the lamp has been fully cooled down, the

READY indicator changes to green blinking. In
this condition, the projection lamp is turned on if
the input signal is reconnected or any button on
the top control or remote control unit is pressed.

Shut down . . .When the lamp has been fully cooled down, the

power is turned off.

Off . . . . . . . . .The Power Management function is canceled.

Timer Setting
Move the pointer to the
timer and set time with the
Point buttons

(e and d)

or

the Control pad and press
the SELECT button. The
timer window disappears
and then choose “Ready” or
“Shutdown” to enable the
timer setting.

Note:

When the last selected input source in the Input menu differs from the detected input
source, the projector may not display the image properly. In this case, select input
source.