42 uart control, 43 uart control (sd series) – Vivotek MD9584-HF3 5MP Outdoor Network Mobile Dome Camera with Night Vision, Heater & 3.6mm Lens User Manual

Page 381

Advertising
background image

VIVOTEK

User's Manual - 381

© 2022 VIVOTEK INC. All Right Reserved

250

7.42

UART Control

Group:

uart

(capability_nuart > 0 and capability_fisheye = 0)

NAME

VALUE

SECURITY
(get/set)

DESCRIPTION

ptzdrivers_i<0~19,
127>_name

string[40]

1/4

Name of the PTZ driver.

ptzdrivers_i<0~19,
127>_location

string[128]

1/4

Full path of the PTZ driver.

enablehttptunnel

<boolean>

1/4

Enable HTTP tunnel channel to control
UART.


Group:

uart_i<0~(n-1)>

n is uart port count

(capability_nuart > 0 and capability_fisheye = 0)

NAME

VALUE

SECURITY
(get/set)

DESCRIPTION

baudrate

300,600,1200,2400,
4800,9600,19200,38
400,57600,115200

4/4

Set baud rate of COM port.

databit

5,6,7,8

4/4

Data bits in a character frame.

paritybit

none,
odd,
even

4/4

For error checking.

stopbit

1,2

4/4

"1"

: One stop bit is transmitted to

indicate the end of a byte.

"2"

: Two stop bits are transmitted to

indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.

uartmode

rs485,
rs232

4/4

RS485 or RS232.

customdrvcmd_i<0~
9>

string[128]

1/4

PTZ command for custom camera.
* only available when
capability_camctrl_c0_rs485=2

© 2022 VIVOTEK INC. All Right Reserved

251

NAME

VALUE

SECURITY
(get/set)

DESCRIPTION

speedlink_i<0~4>_n
ame

string[40]

1/4

Additional PTZ command name.
* only available when
capability_camctrl_c0_rs485=2

speedlink_i<0~4>_c
md

string[40]

1/4

Additional PTZ command list.
* only available when
capability_camctrl_c0_rs485=2

ptzdriver

0~19,
127 (custom),
128 (no driver)

1/4

The PTZ driver is used by this COM
port.
* only available when
capability_camctrl_c0_rs485=2

7.43

UART Control (SD Series)

Group:

uart_i<0~(n-1)>

n is uart port count

(capability_nuart > 0 and the bit7 of

capability_ptzenabled is 0, the bit4 of capability_ptzenabled is 1)

NAME

VALUE

SECURITY
(get/set)

DESCRIPTION

cameraid

1~255

4/4

Camera ID controlling external PTZ
camera.
Note:
Please set your speed dome to the
appropriate baud rate, and Camera ID,
e.g. 2400bps, camera ID 1,2,3,,,,etc.
All Camera IDs on the same controlling
system (NVR or rs485 keyboard) have to
be distinct.
Therefore, once you send a controlling
signal, each camera will only accept the
inputs with the corresponding ID.

baudrate

2400,4800,9600,19
200,38400,57600,1
15200

4/4

Set baud rate of COM port.

databit

5,6,7,8

4/4

Data bits in a character frame.

paritybit

none,
odd,
even

4/4

For error checking.

Advertising