Option Interface Connector

Interface type

For use with the optional automatic
document feeder (B813162) and
transparency unit (B813182)

Output voltage

21.6 to 26.4 VDC
4.75 to 5.25 VDC

Output current

0.6 A (24 V)
0.3 A (5 V)

Initialization Methods

SCSI interface

Hardware:

Initialized when the scanner is turned on
or the scanner receives a SCSI Reset signal
from the SCSI interface

Software:

Initialized when the software sends the
Esc @ (initialize the scanner command),
or the scanner receives a SCSI Bus Device
message

USB interface

Hardware:

Initialized when the scanner is turned on
or the USB cable is unplugged from the
USB port on the scanner

Software:

Initialized when the software sends the
Esc @ command or the scanner receives a
Bus Reset from the USB interface

Transparency Unit (B813182)

General

Reliability

MCBF 100,000 cycles

Readable area

8.5

×

11.7 inches (216

×

297 mm)

Dimensions

Width: 12.8 inches (324 mm)
Depth: 21.3 inches (540 mm)
Height: 3.6 inches (92 mm)

Weight

Approximately 11 lb (6 kg)

Electrical

Input voltage

21.6 to 26.4 VDC
4.75 to 5.25 VDC

Rated current

0.6 A
0.1 A

Environmental

Temperature

Operating: 41 to 95 °F (5 to 35 °C)
Standby:

14 to 140 °F

(

20 to 60 °C)

Humidity (without
condensation)

Operating: 10 to 80%
Standby:

10 to 85%

Automatic Document Feeder (B813162)

General

Paper
input/output

Load face up; eject face down

Paper quantity

30 pages (55 g/m

2

paper, maximum total

thickness under 0.24 inches [6 mm])

Reliability

100,000 sheets (load/eject MCBF)

Dimensions

Width: 12.2 inches (310 mm)
Depth: 20.9 inches (528 mm)
Height: 3.6 inches (92 mm)

Weight

Approximately 9.9 lb (4.5 kg)

Electrical

Input voltage

22.8 to 25.2 VDC
4.75 to 5.25 VDC

Input current

24 V: 0.6 A
5 V: 0.3 A

Environmental

Temperature

Operating: 50 to 89 °F (10 to 32 °C)
Standby:

4 to 140 °F (

20 to 60 °C)

Humidity (without
condensation)

Operating: 20 to 80%
Standby:

95% or less